SFBEAM, Elem, LKEY, Lab, VALI, VALJ, VAL2I, VAL2J, IOFFST, JOFFST, LENRAT
Specifies surface loads on beam and pipe elements.
ElemElement to which surface load is applied.  If ALL,
apply load to all selected beam elements (ESEL).
 If Elem = P, graphical picking is enabled
and all remaining command fields are ignored (valid only in the GUI).
 A component name may be substituted in Elem.
LKEYLoad key associated with surface load (defaults to 1). Load keys (1, 2, 3, etc.) are listed under "Surface Loads" in the input table for each element type in the Element Reference. For beam and some pipe elements, the load key defines the load orientation.
LabValid surface load label. Load labels are listed under "Surface Loads" in the input table for each element type in the Element Reference. Structural labels: PRES (pressure).
VALI, VALJSurface load values at nodes I and J.  If VALJ is blank, it defaults to VALI.  If VALJ is zero, a zero is used.
VAL2I, VAL2JSecond surface load values at nodes I and J. Currently not used.
IOFFST, JOFFSTOffset distance from node I (toward node J) where VALI is applied, and offset distance from node J (toward
node I) where VALJ is applied, respectively.
 
LENRATOffset distance flag:
0  | —  | Offset is in terms of length units (default).  | 
1  | —  | Offset is in terms of a length ratio (0.0 to 1.0).  | 
Specifies surface loads on the selected beam elements. Distributed loads are applied on a force-per-length basis (that is, the width of the underlying element is not considered). To list and delete surface loads applied with this command, use the SFELIST and SFEDELE commands, respectively.
If no offset values (IOFFSET and JOFFSET) are specified, the load is applied over the
full element length. Values may also be input as length fractions,
depending on the LENRAT setting. For example,
assuming a line length of 5.0, an IOFFST of 2.0 with LENRAT = 0 or an IOFFST of 0.4 with LENRAT = 1 represent the same point.  If JOFFST = -1, VALI is assumed to be a point load
at the location specified via IOFFST, and VALJ is ignored. (IOFFSET cannot be equal to -1.) The offset values are stepped even if you
issue a KBC,0 command.
Offsets are only available for element types BEAM188 and PIPE288 if using the cubic shape function (KEYOPT(3) = 3) for those element types.
To accumulate (add) surface loads applied with this command, use the SFCUM,,ADD command. Use the same offset values used on the previous SFBEAM command (for a given element face); otherwise, the loads do not accumulate. If no offsets are specified, the command applies the previous offset values.
This command is also valid in PREP7.