MAP, --, kDIM, --, kOUT, LIMIT
Maps pressures from source points to target surface elements.
--Unused field.
kDIMInterpolation key:
0 or 2  | —  | Interpolation is done on a surface (default).  | 
3  | —  | Interpolation is done within a volume. This option is useful if the supplied source data is volumetric field data rather than surface data.  | 
--Unused field.
kOUTKey to control how pressure is applied when a target node is outside of the source region:
0  | —  | Use the pressure(s) of the nearest source point for target nodes outside of the region (default).  | 
1  | —  | Set pressures outside of the region to zero.  | 
LIMITNumber of nearby points considered for interpolation.
The minimum is 5; the default is 20. Lower values reduce processing
time. However, some distorted or irregular meshes will require a higher LIMIT value to find the points encompassing the target